Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GMB631PC5CIR BRK THRM-MAG 5A 240VAC/60VDC |
2,813 | - |
|
Datasheet | GMB63 | Box | Active | DIN Rail | Thermal Magnetic | 5A | 240 V | 60 V | Lever | 1 | None | - | CSA C22.2 No 5, IEC 60947-2, UL489 |
|
GMB631PC13CIR BRK THERM-M 13A 240VAC/60VDC |
4,661 | - |
|
Datasheet | GMB63 | Box | Active | DIN Rail | Thermal Magnetic | 13A | 240 V | 60 V | Lever | 1 | None | - | CSA C22.2 No 5, IEC 60947-2, UL489 |
|
T29-7721-1CIRCUIT BREAKER MAG-HYDR TOGGLE |
6,976 | - |
|
Datasheet | SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Toggle | 2 | - | - | - |
|
2907516CIR BRKR 20A 480VAC 125VDC |
4,545 | - |
|
Datasheet | TMC 8 | Box | Active | DIN Rail | Thermal Magnetic | 20A | 480 V | 125 V | Lever | 2 | - | - | cULus, UL489 |
|
2907661CIR BRKR 13A 480VAC 125VDC |
3,075 | - |
|
Datasheet | TMC 8 | Box | Active | DIN Rail | Thermal Magnetic | 13A | 480 V | 125 V | Lever | 2 | - | - | cULus, UL489 |
|
2907672CIR BRKR 60A 240VAC 125VDC |
1,993 | - |
|
Datasheet | TMC 8 | Box | Active | DIN Rail | Thermal Magnetic | 60A | 240 V | 125 V | Lever | 2 | - | - | cULus, UL489 |
|
2907666CIR BRKR 25A 480VAC 125VDC |
2,261 | - |
|
Datasheet | TMC 8 | Box | Active | DIN Rail | Thermal Magnetic | 25A | 480 V | 125 V | Lever | 2 | - | - | cULus, UL489 |
|
W91-X113-5CIR BRKR MAG-HYDR 5A 277VAC |
2,893 | - |
|
Datasheet | W9 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 277 V | - | Lever | 1 | - | - | - |
|
2-5700-IG1-K10-DD-3ACIR BRKR THRM 3A 250VAC 50VDC |
2,848 | - |
|
Datasheet | 2-5700 | Bulk | Active | Panel Mount | Thermal | 3A | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
GSB633PC32MCB UL1077 C 3P 32A |
3,782 | - |
|
Datasheet | GSB63 | Box | Active | DIN Rail | Thermal Magnetic | 32A | 480 V | - | Lever | 3 | None | - | UL1077 |
|
GSB633PC25MCB UL1077 C 3P 25A |
1,903 | - |
|
Datasheet | GSB63 | Box | Active | DIN Rail | Thermal Magnetic | 25A | 480 V | - | Lever | 3 | None | - | UL1077 |
|
GSB633PC16MCB UL1077 C 3P 16A |
4,596 | - |
|
Datasheet | GSB63 | Box | Active | DIN Rail | Thermal Magnetic | 16A | 480 V | - | Lever | 3 | None | - | UL1077 |
|
GSB633PC2MCB UL1077 C 3P 2A |
2,092 | - |
|
Datasheet | GSB63 | Box | Active | DIN Rail | Thermal Magnetic | 2A | 480 V | - | Lever | 3 | None | - | UL1077 |
|
2-5700-IG1-K10-DD-2ACIR BRKR THRM 2A 250VAC 50VDC |
3,469 | - |
|
Datasheet | 2-5700 | Bulk | Active | Panel Mount | Thermal | 2A | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
4410.0655CIR BRKR THRM 1A 240VAC 28VDC |
3,852 | - |
|
Datasheet | T12 | Bulk | Active | Panel Mount | Thermal | 1A | 240 V | 28 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
|
4230-T130-K0BE-20ACIR BRKR THERM 20A 480VAC/125VDC |
3,421 | - |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 20A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL489 |
|
2-5700-IG2-K10-DD-25ACIR BRKR THRM 25A 250VAC 50VDC |
3,259 | - |
|
Datasheet | 2-5700 | Bulk | Active | Panel Mount | Thermal | 25A | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
4430.3167CIR BRKR THRM 15A 240VAC 60VDC |
2,618 | - |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | 15A | 240 V | 60 V | Rocker | 2 | - | - | - |
|
4230-T130-K0CE-10ACIR BRKR THERM 10A 480VAC/125VDC |
3,897 | - |
|
Datasheet | 4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 10A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL1077 |
|
IEG6-1-61-1.00-01-VCIR BRKR MAG-HYDR LEVER 1A |
4,896 | - |
|
Datasheet | IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 1A | 250 V | - | Lever | 1 | None | - | CSA, TUV, UL1077 |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.