Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
7940116313CIR BRKR THRMMAG 9A 250VAC 80VDC |
2,735 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 9A | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116312CIR BRKR 100MA 250VAC 80VDC |
7,586 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 100mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940102181CIR BRKR 200MA 250VAC 80VDC |
3,725 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 200mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116421CIR BRKR 300MA 250VAC 80VDC |
9,869 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 300mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116359CIR BRKR 400MA 250VAC 80VDC |
4,169 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 400mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116360CIR BRKR 600MA 250VAC 80VDC |
5,240 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 600mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116406CIR BRKR 700MA 250VAC 80VDC |
3,695 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 700mA | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940102162CIR BRKR 10A 250VAC 80VDC |
8,753 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 10A | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116320CIR BRKR 12A 250VAC 80VDC |
6,682 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 12A | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
7940116321CIR BRKR 14A 250VAC 80VDC |
5,149 | - |
|
Datasheet | CB4200 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 14A | 250 V | 80 V | Push to Reset | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
LELK1-1REC4-27129-903CIR BRKR MAG-HYDR LEVER |
3,703 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
LELK1-1REC4-27129-915CIR BRKR MAG-HYDR LEVER |
9,065 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
|
LELK1-1REC4-27129-923CIR BRKR MAG-HYDR LEVER |
8,217 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
LELK1-1REC4-27129-927CIR BRKR MAG-HYDR LEVER |
3,893 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
LELK1-1REC4-27129-939CIR BRKR MAG-HYDR LEVER |
8,811 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
IULNK1-0-SW-100.CIR BRKR MAG-HYDR 100A TOGGLE |
6,380 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | - | - | Toggle | 1 | - | - | - |
|
IMLK1-1REC5-52-2.50-A-01-VCIR BRKR MAG-HYDR |
3,466 | - |
|
Datasheet | IML | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 2A | 415 V | 80 V | Lever | 1 | None | - | - |
|
IEGS2-29902-1-VCIR BRKR MAG-HYDR LEVER |
4,189 | - |
|
Datasheet | IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | - | - | - | CSA, TUV, UL1077 |
|
8350-AC1B-MACS-L0AB0D-50ACIRC BRKR HYDRAULIC MAGNETIC |
8,547 | - |
|
Datasheet | 8350 | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 50A | 240 V | 80 V | Rocker | 1 | None | - | IEC 60934, UL1077 |
|
AT1-B2-14-615-121-MTCIRCUIT BREAKER |
4,169 | - |
|
Datasheet | A | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 277 V | 65 V | Lever | 1 | None | - | CCC, UL489A |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.