Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BF2-B0-24-620-53A-CGCIRCUIT BREAKER |
6,460 | - |
|
Datasheet | B | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 240 V | 80 V | Rocker | 2 | None | - | CCC, UL489 |
|
5SJ42148HG42MCB 5SJ4 2P 480/277 0.3A 10K D-T |
5,398 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 300mA | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489, VDE |
|
5SJ42057HG42MCB 5SJ4 2P 480/277 0.5A 10K C-T |
5,612 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 500mA | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489, VDE |
|
5SJ42157HG42MCB 5SJ4 2P 480/277 1.6A 10K C-T |
9,866 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 1.6A | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489, VDE |
|
5SJ42147HG42MCB 5SJ4 2P 480/277 0.3A 10K C-T |
6,493 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 300mA | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489, VDE |
|
5SJ42138HG42MCB 5SJ4 2P 480/277 13A 10K D-TR |
8,866 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 13A | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489, VDE |
|
5SJ42257HG42MCB 5SJ4 2P 480/277 25A 10K C-TR |
6,855 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 25A | 400 V | 60 V | Lever | 2 | None | - | CCC, CE, EAC, UL489 |
|
IULZXK1-1-52-20.0-GK-B3CIR BRKR MAG-HYDR 30A ROCKER |
5,675 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | - | - | Rocker | 1 | - | - | - |
|
9925680000CIR BRKR 2A 480VAC 110VDC |
5,811 | - |
|
Datasheet | CB9100 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 2A | 480 V | 110 V | Lever | 2 | - | - | - |
|
8340-F920-K2M2-A2H0-30ACIR BRKR MAG 30A 240VAC 80VDC |
2,031 | - |
|
Datasheet | 8340-F | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | 240 V | 80 V | Lever | 2 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
AK2-B0-20-650-52A-ECIRCUIT BREAKER |
6,722 | - |
|
Datasheet | A | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | 250 V | 80 V | Rocker | 2 | None | - | CCC, CSA, TUV, UL |
|
AK2-B0-24-650-52A-ECIRCUIT BREAKER |
9,516 | - |
|
Datasheet | A | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | 250 V | 80 V | Rocker | 2 | None | - | CCC, CSA, TUV, UL |
|
LUJV66-71195-6CIR BRKR MAG-HYDR |
9,415 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
LELB1-1REG4-53-80.0-A1-01-VCIR BRKR HYD MAG |
8,527 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 80A | 250 V | 80 V | Lever | 1 | None | - | CCC, VDE |
|
IULHK11-1REC4-71266-7CIR BRKR,HYDMAG |
4,392 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK11-1REC4-71266-2CIR BRKR,HYDMAG |
2,377 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK11-1REC4-71266-3CIR BRKR,HYDMAG |
4,713 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK11-1REC4-71266-5CIR BRKR,HYDMAG |
6,433 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK11-1REC4-71266-6CIR BRKR,HYDMAG |
8,026 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
IULHK11-1REC4-71266-4CIR BRKR,HYDMAG |
2,832 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.