| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IUGN66-1-53-15.0-ACIR BRKR MAG-HYDR 15A TOGGLE |
4,574 | - |
|
Datasheet | IUG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | - | - | Toggle | 2 | - | - | - |
|
IUGN66-1-64-35.0CIR BRKR MAG-HYDR 35A TOGGLE |
3,236 | - |
|
Datasheet | IUG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 35A | - | - | Toggle | 2 | - | - | - |
|
GV2L32TESYS MOTOR CB MAG 32A ROT HANDL |
8,460 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Magnetic | 32A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-4-1, IEC 60947-4-1, UL60947-4-1 |
|
CELBXPK11-1REC4-33650-125CIRCUIT BREAKER MAG-HYDR ROCKER |
6,592 | - |
|
Datasheet | CEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Rocker | 2 | - | - | - |
|
CELBXPK11-1REC4-33650-150CIRCUIT BREAKER MAG-HYDR ROCKER |
5,579 | - |
|
Datasheet | CEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Rocker | 2 | - | - | - |
|
CELBXPK11-1REC4-33650-200CIRCUIT BREAKER MAG-HYDR ROCKER |
6,121 | - |
|
Datasheet | CEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Rocker | 2 | - | - | - |
|
IELHK112-30097-1CIRCUIT BREAKER MAG-HYDR LEVER |
3,866 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | - | - | - | - |
|
CX2-B0-12-810-32A-06CCIRCUIT BREAKER |
6,969 | - |
|
Datasheet | CX | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | - | 600 V | Lever | 2 | None | - | CCC, UL1077 |
|
IELHK111-1REG4-62-50.0-01-VCIR BRKR MAG-HYDR LEVER 50A |
5,248 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | - | - | Lever | 3 | - | - | - |
|
IELHK111-1REG4-63-15.0-AE-01-VCIR BRKR MAG-HYDR LEVER 15A |
3,332 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 480 V | - | Lever | 3 | - | - | - |
|
IELHK111-1REG4-62-15.0-01-VCIR BRKR MAG-HYDR 15A LEVER |
6,919 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | - | - | Lever | 3 | - | - | - |
|
IULN111-1REC4-62F-40.0-DCIR BRKR MAG-HYDR 40A TOGGLE |
6,599 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 40A | - | - | Toggle | 3 | - | - | - |
|
CA3-B2-26-650-422-CFCIRCUIT BREAKER |
2,240 | - |
|
Datasheet | C | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | 240 V | 150 V | Lever | 3 | None | - | CCC, CSA, UL489, VDE |
|
CELHPK11-1REC5-32933-200CIRCUIT BREAKER MAG-HYDR LEVER |
5,401 | - |
|
Datasheet | CEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 2 | - | - | - |
|
LMLHPB11-1-51-150.-1-01-VCIR BRKR HYD MAG |
2,286 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
LELBXPB11-1REC4-71215-125CIR BRKR MAG-HYDR |
9,226 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | 415 V | 80 V | Rocker | 2 | None | - | - |
|
GA3-B0-22-250-11-HECIRCUIT BREAKER |
5,275 | - |
|
Datasheet | G | Bulk | Active | DIN Rail | Magnetic (Hydraulic Delay) | 500mA | 480 V | 125 V | Lever | 3 | None | - | CCC, TUV, UL |
|
CMLHPB11-1RLS4-70346-1-VCIR BRKR,HYDMAG |
4,696 | - |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - |
|
8345-B01A-V3M2-DB1B1B-X8345-R12010001M-20ACIR BRKR THRM 20A |
5,655 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 480 V | 80 V | Lever | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
M9F14232MULTI9 C60H 2P C 32A 15KA 415V M |
4,188 | - |
|
Datasheet | Multi9 | Box | Active | DIN Rail | Thermal Magnetic | 32A | 440 V | 125 V | Toggle | 2 | None | - | EN 60947-2, IEC 60947-2 |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.