Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EA4-B0-26-810-22A-DCCIRCUIT BREAKER |
2,656 | - |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | 240 V | 125 V | Lever | 4 | None | - | CCC, CSA, UL489 |
|
EA4-B0-24-680-22A-JDCIRCUIT BREAKER |
3,527 | - |
|
Datasheet | E | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 80A | 415 V | 125 V | Lever | 4 | None | - | CCC, CSA, UL1077, VDE |
|
209-3-27718-13CIR BRKR MAG-HYDR LEVER |
7,669 | - |
|
Datasheet | 209 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 3 | None | - | - |
|
8345-F23A-V3V2-282050-5ACIRC BRKR HYDRAULIC MAGNETIC |
9,764 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3M2-282050-10ACIRC BRKR HYDRAULIC MAGNETIC |
7,814 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3V2-282050-10ACIRC BRKR HYDRAULIC MAGNETIC |
7,779 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3V2-282050-25ACIRC BRKR HYDRAULIC MAGNETIC |
5,453 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3V2-282050-30ACIRC BRKR HYDRAULIC MAGNETIC |
9,928 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3V2-282050-40ACIRC BRKR HYDRAULIC MAGNETIC |
7,280 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 40A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3V2-282050-60ACIRC BRKR HYDRAULIC MAGNETIC |
4,616 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 60A | 415 V | 80 V | Lever | 3 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-F23A-V3M2-282050-30AMIN ORD QTY 10. SINGLE OR MULTIP |
7,242 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
8345-F23A-V3M2-282050-25AMIN ORD QTY 10. SINGLE OR MULTIP |
4,363 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
8345-F23A-V3M2-282050-5AMIN ORD QTY 10. SINGLE OR MULTIP |
6,088 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
8345-F23A-V3M2-282050-15AMIN ORD QTY 10. SINGLE OR MULTIP |
7,352 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
C103TM025TRIP UNIT NSX100 AC 3P3D 25A TMD |
8,499 | - |
|
Datasheet | ComPacT | Box | Obsolete | Chassis Mount | Thermal Magnetic | 25A | 690 V | - | Lever | 3 | None | - | EN 60947-2, IEC 60947-2 |
|
C103TM040TRIP UNIT NSX100 AC 3P3D 40A TMD |
2,436 | - |
|
Datasheet | ComPacT | Box | Obsolete | Chassis Mount | Thermal Magnetic | 40A | 690 V | - | Lever | 3 | None | - | EN 60947-2, IEC 60947-2 |
|
C103TM050TRIP UNIT NSX100 AC 3P3D 50A TMD |
8,684 | - |
|
Datasheet | ComPacT | Box | Obsolete | Chassis Mount | Thermal Magnetic | 50A | 690 V | - | Lever | 3 | None | - | EN 60947-2, IEC 60947-2 |
|
IELHK1111-1REC4-66F-40.0-A-01CIR BRKR MAG-HYDR |
2,111 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 40A | 415 V | 80 V | Lever | 4 | None | - | - |
|
CB3-B0-22-672-361-RCIRCUIT BREAKER |
6,506 | - |
|
Datasheet | C | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 72A | 277 V | 150 V | Lever | 3 | None | - | CCC, CSA, TUV, UL489 |
|
CA4-B0-44-620-1DA-CCIRCUIT BREAKER |
8,196 | - |
|
Datasheet | C | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 480 V | 150 V | Lever | 4 | None | - | CCC, CSA, UL |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.