Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3VA51406EF410AA0BRKR 3VA51 4P 40A 65KA ATAM |
3,748 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 40A | 690 V | - | Lever | 4 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
203-111-23927-1CIR BRKR ROCKER |
8,826 | - |
|
Datasheet | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | UL1077 |
|
HDL26030CMOLDED CASE CIRCUIT BREAKER 600V |
6,887 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 30A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
|
3VA51606EC320AA0BRKR 3VA51 3P 60A 65KA FTAM NUT |
5,959 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 60A | 690 V | - | Lever | 3 | None | - | CCC, UL489 |
|
AP12-3-41-153CIR BRKR HYD MAG |
7,135 | - |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 15A | 240 V | 50 V | Toggle | 2 | None | - | CSA, UL1077 |
|
3VA51114GC410AA0BRKR 3VA51 4P 110A 25KA FTAM 100 |
7,796 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 110A | 690 V | - | Lever | 4 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
3VA51114EC410AA0BRKR 3VA51 4P 110A 25KA FTAM |
7,577 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 110A | 690 V | - | Lever | 4 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
AP12-1RC-72-752CIR BRKR HYD MAG |
4,499 | - |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 7.5A | 240 V | 50 V | Toggle | 2 | None | - | CSA, UL1077 |
|
BDA34090YMOLDED CASE CIRCUIT BRKR 480Y/27 |
5,763 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 90A | 525 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA34070YMOLDED CASE CIRCUIT BRKR 480Y/27 |
5,317 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 70A | 525 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA34100YMOLDED CASE CIRCUIT BRKR 480Y/27 |
7,296 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 100A | 525 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDA34080YMOLDED CASE CIRCUIT BRKR 480Y/27 |
2,530 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 80A | 525 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
AP12-1R-25352-1CIR BRKR HYD MAG |
4,764 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
3VA51124ED221AA0BRKR 3VA51 2P 125A 25KA FTFM NAV |
6,232 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 125A | 415 V | - | Lever | 2 | None | - | CCC, UL489 |
|
3VA51124ED310AA0BRKR 3VA51 3P 125A 25KA FTFM |
6,866 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 125A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
447-K-H-FN-SI-225ACIR BRKR THRM 225A |
5,635 | - |
|
Datasheet | 447 | Bulk | Active | Chassis Mount | Thermal Magnetic | 225A | - | 28 V | Push to Reset | 1 | None | - | CSA C22.2 No 235, UL1077 |
|
3VA51124ED261AA0BRKR 3VA51 2P 125A 25KA FTFM NAV |
5,576 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 125A | 415 V | - | Lever | 2 | None | - | CCC, CE, UL489, VDE |
|
AP12-1R-72-501CIR BRKR HYD MAG |
8,978 | - |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 500mA | 240 V | 50 V | Toggle | 2 | None | - | CSA, UL1077 |
|
AP12-1R-3062-17CIR BRKR HYD MAG |
2,162 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
AP12-1R-72F-102CIR BRKR HYD MAG |
5,878 | - |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 1A | 240 V | 50 V | Toggle | 2 | None | - | CSA, UL1077 |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.