Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AP116-7064-225CIR BRKR HYD MAG |
9,251 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
AP116-7064-231CIR BRKR, HYDMAG, 3 PL, 80VDC/25 |
8,849 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
AP116-7064-249CIR BRKR, HYDMAG, 3 PL, 50VDC/25 |
6,490 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
AP116-7064-255CIR BRKR, HYDMAG, 3 PL, 80VDC/25 |
3,903 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - |
|
EJB26050MINIATURE CIRCUIT BREAKER 600V 5 |
6,047 | - |
|
Datasheet | - | Box | Obsolete | Chassis Mount | Thermal Magnetic | 50A | - | - | Lever | 2 | None | - | cULus |
|
EJB26025MINIATURE CIRCUIT BREAKER 600V 2 |
8,527 | - |
|
Datasheet | - | Box | Obsolete | Chassis Mount | Thermal Magnetic | 25A | 600 V | - | Lever | 2 | None | - | cULus |
|
EJB24020AABAMINIATURE CIRCUIT BREAKER 480Y/2 |
6,494 | - |
|
Datasheet | - | Box | Obsolete | - | - | - | - | - | - | - | - | - | - |
|
HLL36050M72MOTOR CIRCUIT PROTECTOR 600V 50A |
4,890 | - |
|
Datasheet | PowerPact | Box | Obsolete | Panel Mount | Solid State | 50A | 600 V | - | Lever | 3 | None | - | CCC, CE, IEC, UR |
|
3VA52106ED610AA0BRKR 3VA52 2(3)P 100A 65KA FTFM |
2,968 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 100A | 690 V | - | Lever | 2 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
3VA52200MU360AA0BRKR 3VA52 3P 200A 65KA MCP LO A |
6,169 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 200A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA |
|
3VA52200MH360AA0BRKR 3VA52 3P 200A 65KA MCP HI A |
3,943 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 200A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA |
|
AP112-1R-71F-252CIR BRKR,HYDMAG |
7,208 | - |
|
Datasheet | AP | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 2.5A | 240 V | 50 V | Toggle | 3 | None | - | CSA, UL1077 |
|
3VA52805ED322AA0BRKR 3VA52 3P 80A 35KA FTFM 100 |
6,213 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 80A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
EDB34015SACAMINIATURE CIRCUIT BREAKER 480Y/2 |
7,439 | - |
|
Datasheet | - | Box | Obsolete | - | - | - | - | - | - | - | - | - | - |
|
HGA260906MOLDED CASE CIRCUIT BREAKER 600V |
8,556 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 90A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
|
HGA261005MOLDED CASE CIRCUIT BREAKER 600V |
2,463 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 100A | 690 V | - | Toggle | 2 | None | - | CSA, IEC 60947-2, UL |
|
HGA261002MOLDED CASE CIRCUIT BREAKER 600V |
8,647 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 100A | 690 V | 500 V | Toggle | 2 | None | - | CSA, UL |
|
HJL26050MOLDED CASE CIRCUIT BREAKER 600V |
9,849 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 50A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
|
HGA260706MOLDED CASE CIRCUIT BREAKER 600V |
5,303 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 70A | 240 V | 250 V | Toggle | 2 | None | - | CSA, IEC 60947-2, UL |
|
HJL26060MOLDED CASE CIRCUIT BREAKER 600V |
2,967 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 60A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.