| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3VA52607ED610AA0BRKR 3VA52 2(3)P 60A 100KA FTFM |
6,761 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 60A | 690 V | - | Lever | 2 | None | - | CCC, CE, CSA, EAC, UL489 |
|
3VA51126ED261AA0BRKR 3VA51 2P 125A 65KA FTFM NAV |
3,348 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 125A | 415 V | - | Lever | 2 | None | - | CCC, CE, UL489, VDE |
|
HGL36060CMOLDED CASE CIRCUIT BREAKER 600V |
2,456 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 60A | - | - | Toggle | 3 | None | - | CSA, UL |
|
HGL36015CMOLDED CASE CIRCUIT BREAKER 600V |
8,240 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 15A | 690 V | - | Toggle | 3 | None | - | CSA, UL |
|
HGL36050CMOLDED CASE CIRCUIT BREAKER 600V |
7,832 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 50A | 690 V | - | Toggle | 3 | None | - | CSA, UL |
|
HGL36020CMOLDED CASE CIRCUIT BREAKER 600V |
4,441 | - |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Thermal Magnetic | 20A | 690 V | - | Toggle | 3 | None | - | CSA, IEC 60947-2, UL |
|
BDF36125MOLDED CASE CIRCUIT BRKR 600Y/34 |
4,709 | - |
|
Datasheet | PowerPact | Box | Obsolete | DIN Rail | Thermal Magnetic | 125A | 525 V | - | Toggle | 3 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
3VA52125EF312AA0BRKR 3VA52 3P 125A 35KA ATAM 100 |
8,220 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 125A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
3VA52205EC322AA0BRKR 3VA52 3P 200A 35KA FTAM 100 |
8,977 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 200A | 690 V | 750 V | Lever | 3 | None | - | - |
|
3VA52175EC322AA0BRKR 3VA52 3P 175A 35KA FTAM 100 |
2,223 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 175A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
3VA52105EF312AA0BRKR 3VA52 3P 100A 35KA ATAM 100 |
6,187 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 100A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
3VA52155EF312AA0BRKR 3VA52 3P 150A 35KA ATAM 100 |
6,267 | - |
|
Datasheet | 3VA5 | Bulk | Active | DIN Rail | - | 150A | 690 V | 750 V | Lever | 3 | None | - | UL |
|
3VA52205EC361AA0BRKR 3VA52 3P 200A 35KA FTAM NAV |
2,774 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 200A | 690 V | - | Lever | 3 | None | - | CCC, CE, UL489 |
|
3VA52175EC361AA0BRKR 3VA52 3P 175A 35KA FTAM NAV |
9,070 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 175A | 690 V | - | Lever | 3 | None | - | CCC, CE, UL489 |
|
HGL26080CMOLDED CASE CIRCUIT BREAKER 600V |
3,026 | - |
|
Datasheet | - | Box | Active | Chassis Mount | Thermal Magnetic | 80A | 690 V | - | Toggle | 2 | None | - | CSA, UL |
|
HGL26070CMOLDED CASE CIRCUIT BREAKER 600V |
9,922 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 70A | 690 V | - | Toggle | 2 | None | - | CSA, UL, IEC 60947-2 |
|
HGL26100CMOLDED CASE CIRCUIT BREAKER 600V |
6,531 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 100A | 690 V | - | Toggle | 2 | None | - | CSA, IEC 60947-2, UL |
|
3VA52706ED360AA0BRKR 3VA52 3P 70A 65KA FTFM AL |
8,890 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 70A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, UL489 |
|
3VA52906ED360AA0BRKR 3VA52 3P 90A 65KA FTFM AL |
6,859 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 90A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, UL489 |
|
HGP36000S15AUTOMATIC MOLDED CASE SWITCH 600 |
5,625 | - |
|
Datasheet | PowerPact | Box | Obsolete | Chassis Mount | Magnetic | 150A | 600 V | - | Lever | 3 | None | - | CCC, CE, CSA, IEC, NMX, UL |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.