Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
4420.0808CIR BRKR THRM MAG 15A 360 VDC |
5,715 | - |
|
Datasheet | AS168XDC3 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 15A | - | 360 V | Lever | 3 | - | - | CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
|
4420.0686CIR BRKR THRM MAG 50A 480V 65V |
4,647 | - |
|
Datasheet | AS168XAC3 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 50A | 480 V | 65 V | Lever | 3 | - | - | CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
|
4420.0762CIR BRKR THRM MAG 50A 480V 65V |
4,090 | - |
|
Datasheet | AS168XAC3 | Bulk | Obsolete | DIN Rail | Thermal Magnetic | 50A | 480 V | 65 V | Lever | 3 | - | - | CSA C22.2 No 14, CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077, UL508 |
|
8345-C01A-R0M0-DB1A1B-125ACIR BRKR 125A 240VAC 80VDC |
4,511 | - |
|
Datasheet | 8345 | Bulk | Obsolete | Panel Mount | Magnetic (Hydraulic Delay) | 125A | 480 V | 80 V | Lever | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
8345-C02A-R0M0DB1A1B-125ACIR BRKR 125A 240VAC 80VDC |
8,285 | - |
|
Datasheet | 8345 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 125A | 480 V | 80 V | Lever | 2 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
3120-F321-P7T1-W14FB3-2.5ACIR BRKR THRM 2.5A 250VAC 50VDC |
9,894 | - |
|
Datasheet | 3120-F | - | Obsolete | Panel Mount | Thermal | 2.5A | 250 V | 50 V | Rocker | 2 | Red | 90V | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
3120-F32G-P7T1-D01X-10ACIR BRKR THRM 10A 250VAC 50VDC |
6,616 | - |
|
Datasheet | 3120-F | Bag | Obsolete | Panel Mount | Thermal | 10A | 250 V | 50 V | Pushbutton | 2 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
2-5700-IG1-P10-DD-0.5ACIR BRKR THRM 500MA 250VAC 50VDC |
9,398 | - |
|
Datasheet | 2-5700 | Bulk | Active | Panel Mount | Thermal | 500mA | 250 V | 50 V | Push-Push | 1 | None | - | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
W91-X152-5CIR BRKR MAG-HYDR 5A 65VDC |
9,144 | - |
|
Datasheet | W9 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | - | 65 V | Toggle | 1 | - | - | - |
|
W33-S3B1Q-15CIR BRKR THRM 15A 250VAC 50VDC |
7,526 | - |
|
Datasheet | W33 | Bulk | Active | Panel Mount | Thermal | 15A | 250 V | 50 V | Rocker | 2 | Red | 120V | - |
|
W54-XC7A4A10-30CIR BRKR THRM 30A 250VAC |
8,198 | - |
|
Datasheet | W54 | Tray | Obsolete | Panel Mount | Thermal | 30A | 250 V | - | Push to Reset | 1 | - | - | - |
|
W54-XC2A4B10-40CIR BRKR THRM 40A 250VAC |
8,412 | - |
|
Datasheet | W54 | Tray | Obsolete | Panel Mount | Thermal | 40A | 250 V | - | Push to Reset | 1 | - | - | - |
|
W28-XQ31C-15CIR BRKR THRM 15A 250VAC 32VDC |
7,467 | - |
|
Datasheet | W28 | Bulk | Active | Panel Mount | Thermal | 15A | 250 V | 32 V | Push to Reset | 1 | - | - | - |
|
W33-S2N1Q-5CIR BRKR THRM 5A 250VAC 50VDC |
2,100 | - |
|
Datasheet | W33 | Bulk | Active | Panel Mount | Thermal | 5A | 250 V | 50 V | Rocker | 2 | - | - | - |
|
4435.0007CIR BRKR THRM 240VAC 32VDC |
2,099 | - |
|
Datasheet | TA35 | Bulk | Obsolete | Panel Mount | Thermal | - | 240 V | 32 V | Rocker | 1 | - | - | - |
|
3120-F32G-P7T1-D19XL4-5ACIR BRKR THRM 5A 250VAC 50VDC |
2,197 | - |
|
Datasheet | 3120-F | Bag | Obsolete | Panel Mount | Thermal | 5A | 250 V | 50 V | Pushbutton | 2 | Green | 185V | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
|
IEG1-1-72-25.0-91-VCIR BRKR 25A 250VAC 80VDC |
2,687 | - |
|
Datasheet | IEG | Tray | Active | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 250 V | 80 V | Lever | 1 | - | - | CSA, TUV, UL1077 |
|
LELHK111-36578-20-VCIR BRKR 20A 240VAC 80VDC |
4,845 | - |
|
Datasheet | LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 240 V | 80 V | Lever | 3 | - | - | - |
|
AP112-1R-36616-1CIR BRKR MAG-HYDR 240VAC 50VDC |
6,163 | - |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | 240 V | 50 V | Toggle | 3 | - | - | - |
|
AP12-1T-28180-8CIR BRKR MAG-HYDR 240VAC 50VDC |
6,283 | - |
|
Datasheet | AP | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | 240 V | 50 V | Toggle | 2 | - | - | - |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.