Circuit Breakers
Browse available Circuit Breakers components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GV2P21TESYS MOTOR CIRCUIT BREAKER |
8,340 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 23A | 690 V | 690 V | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
|
IULHK1111-1REC4R-65F-35.0-01CIR BRKR MAG-HYDR |
1,118 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | 415 V | 80 V | Lever | 4 | None | - | - |
|
452-K14-FN2-100ACIR BRKR THRM-MAG 100A 28VDC |
4,466 | - |
|
Datasheet | 452 | Bulk | Active | Panel Mount | Thermal Magnetic | 100A | - | 28 V | Push-Pull Plunger | 1 | None | - | CSA C22.2 No 235, UL1077 |
|
BDL16015MOLDED CASE CIRCUIT BREAKER 347V |
2,106 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 15A | 240 V | - | Toggle | 1 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL16020MOLDED CASE CIRCUIT BREAKER 347V |
2,175 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 20A | 240 V | - | Toggle | 1 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL16030MOLDED CASE CIRCUIT BREAKER 347V |
3,559 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 30A | 240 V | - | Toggle | 1 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL16050MOLDED CASE CIRCUIT BREAKER 347V |
2,271 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 50A | 240 V | - | Toggle | 1 | None | - | EN 60947-2, IEC 60947-2 |
|
219-3-4884-3CIRCUIT BREAKER MAG-HYDR LEVER |
3,677 | - |
|
Datasheet | 219 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | 600 V | 125 V | Lever | 3 | None | - | CSA, cULus, UL508, VDE |
|
GV3P32TESYS MOTOR CB THO/MAG 23-32A EV |
2,572 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 32A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GV3P18TESYS MOTOR CB THO/MAG 12-18A EV |
4,831 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 18A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GV3P25TESYS MOTOR CB THO/MAG 17-25A EV |
3,439 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 25A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GV3L65TESYS MOTOR CB MAGNETIC 65A EVLK |
3,312 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Magnetic | 65A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GV3P40TESYS MOTOR CB THO/MAG 30-40A EV |
1,703 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 40A | 690 V | 690 V | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
GV3P50TESYS 3P MOTOR CB THO/MAG 37-50A |
1,200 | - |
|
Datasheet | TeSys | Box | Active | DIN Rail | Thermal Magnetic | 50A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
|
3VA51104ED310AA0BRKR 3VA51 3P 100A 25KA FTFM |
3,888 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 100A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
BDL26025MOLDED CASE CIRCUIT BRKR 600Y/34 |
2,843 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 25A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
|
BDL26035MOLDED CASE CIRCUIT BRKR 600Y/34 |
1,550 | - |
|
Datasheet | PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 35A | 525 V | - | Toggle | 2 | None | - | CSA, EN 60947-2, EN 60947-5-1, IEC 60947-2, IEC 60947-5-1, UL489 |
|
3VA51506ED310AA0BRKR 3VA51 3P 50A 65KA FTFM |
2,222 | - |
|
Datasheet | SENTRON | Box | Active | DIN Rail | - | 50A | 690 V | - | Lever | 3 | None | - | CCC, CE, CSA, EAC, UL489, VDE |
|
HDL26040MOLDED CASE CIRCUIT BREAKER 600V |
1,459 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 40A | 600 V | 250 V | Toggle | 2 | None | - | CSA, UL |
|
HDL26030MOLDED CASE CIRCUIT BREAKER 600V |
3,631 | - |
|
Datasheet | PowerPact | Box | Active | Chassis Mount | Thermal Magnetic | 30A | 690 V | 250 V | Toggle | 2 | None | - | CSA, UL |
Circuit Breakers FAQ
What Circuit Breakers components can I source from EGOO?
You can browse available Circuit Breakers product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Circuit Breakers parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.