| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ISOBLOCK I-ZF (2000AAC 7VAC )ZERO FLUX CURRENT SENSOR |
3,759 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Ratiometric, Voltage | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (2000A 10V)ZERO FLUX CURRENT SENSOR |
3,690 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (1500A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
2,171 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (1500A 5V)ZERO FLUX CURRENT SENSOR |
2,788 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (2000A 5V)ZERO FLUX CURRENT SENSOR |
2,426 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
CD 1000-T/SP7TRANSDUCER |
2,765 | - |
|
Datasheet | CD | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate | 10A | 1 | Current | - | DC ~ 20kHz | - | - | ±24V | - | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
GT1218GROUND FAULT SENSOR CURRENT TRAN |
1,551 | - |
|
Datasheet | - | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ISOBLOCK I-ZF (1500A 10V 0.02%)ZERO FLUX CURRENT SENSOR |
2,458 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (2000A 10V 0.02%)ZERO FLUX CURRENT SENSOR |
2,640 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (1500A 5V 0.02%)ZERO FLUX CURRENT SENSOR |
4,826 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (2000A 5V 0.02%)ZERO FLUX CURRENT SENSOR |
3,209 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
ISOBLOCK I-ZF (2000AAC 7VAC 0.02%)ZERO FLUX CURRENT SENSOR |
4,567 | - |
|
Datasheet | IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Ratiometric, Voltage | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
|
LT 10000-STRANSDUCER |
4,208 | - |
|
Datasheet | LT | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 10000A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±48V ~ 60V | 1µs | 40mA | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
DL2000UB-10VCURRENT TRANSDUCER 2000A |
2,341 | - |
|
Datasheet | DL | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.002% | - | ±14.25V ~ 15.75V | 1µs | 190mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
3-1616987-3HECS6001=HALL EFFECT CURRENT SEN |
2,082 | - |
|
Datasheet | - | Module | Bulk | Active | DC | Hall Effect | 600A | 1 | Voltage | 6.67mV/A | - | - | - | 16V ~ 32V | - | 35mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
8-1616988-7HECS6004=HALL EFFECT CURRENT SEN |
2,386 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
3-2252001-3E145S1=OVERCURRENT SENSING CONTA |
4,685 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
3-2252001-4E145P1=OVERCURRENT SENSING CONTA |
3,267 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTS 6-NPSENSOR CURRENT HALL 6A AC/DC |
1,281 | - |
|
Datasheet | LTS | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 15-NPSENSOR CURRENT HALL 15A AC/DC |
3,604 | - |
|
Datasheet | LTS | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
Current Sensors FAQ
What Current Sensors components can I source from EGOO?
You can browse available Current Sensors product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Current Sensors parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.