Photo Mfr. Part # Availability Price Quantity Datasheet Series Package / Case Packaging Product Status Mounting Type Fuse Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Response Time Applications Features Class Approval Agency Operating Temperature Breaking Capacity @ Rated Voltage Size / Dimension Grade Qualification
CCMR2.25HXP Littelfuse Inc.

CCMR2.25HXP

FUSE CRTRDGE 2.25A 600VAC/300VDC

Littelfuse Inc.

6,394 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 2.25A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR02.5HXP Littelfuse Inc.

CCMR02.5HXP

FUSE CRTRDGE 2.5A 600VAC/300VDC

Littelfuse Inc.

7,020 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 2.5A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR02.8HXP Littelfuse Inc.

CCMR02.8HXP

FUSE CRTRDGE 2.8A 600VAC/300VDC

Littelfuse Inc.

5,916 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 2.8A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR003.HXP Littelfuse Inc.

CCMR003.HXP

FUSE CARTRIDGE 3A 600VAC/300VDC

Littelfuse Inc.

6,522 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 3A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR03.2HXP Littelfuse Inc.

CCMR03.2HXP

FUSE CRTRDGE 3.2A 600VAC/300VDC

Littelfuse Inc.

4,861 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 3.2A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR03.5HXP Littelfuse Inc.

CCMR03.5HXP

FUSE CRTRDGE 3.5A 600VAC/300VDC

Littelfuse Inc.

2,741 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 3.5A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR004.HXP Littelfuse Inc.

CCMR004.HXP

FUSE CARTRIDGE 4A 600VAC/300VDC

Littelfuse Inc.

5,123 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 4A 600 VAC 300 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR04.5HXP Littelfuse Inc.

CCMR04.5HXP

FUSE CRTRDGE 4.5A 600VAC/250VDC

Littelfuse Inc.

7,393 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 4.5A 600 VAC 250 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR005.HXP Littelfuse Inc.

CCMR005.HXP

FUSE CARTRIDGE 5A 600VAC/250VDC

Littelfuse Inc.

3,596 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 5A 600 VAC 250 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
CCMR05.6HXP Littelfuse Inc.

CCMR05.6HXP

FUSE CRTRDGE 5.6A 600VAC/250VDC

Littelfuse Inc.

9,800 -
Datasheet POWR-GARD®, POWR-PRO® CCMR 5AG, 10mm x 38mm (Midget) Bulk Active Requires Holder Cartridge 5.6A 600 VAC 250 VDC Slow Blow Motor Protection - CC CE, CSA, UL - 300kA AC, 20kA DC 0.406" Dia x 1.500" L (10.30mm x 38.10mm) - -
Total 4682 Record«Prev1... 194195196197198199200201...469Next»

Electrical, Specialty Fuses FAQ

How can I narrow the current Electrical, Specialty Fuses selection?

Use the available manufacturer and technical filters to compare matching parts by specifications, stock status, pricing and datasheet information.

Can EGOO help source hard-to-find or obsolete Electrical, Specialty Fuses parts?

Yes. Send the manufacturer part number and required quantity to our sourcing team for availability, lead-time and alternative sourcing support.

Can I request a quotation for a BOM or small-batch requirement?

Yes. EGOO supports BOM sourcing, prototype quantities and small-batch purchasing. Provide your part list and quantities for a quotation review.

What information should I provide when requesting a quote?

Please provide the target part number, manufacturer, quantity and any required date code, package or delivery requirements so our team can respond more accurately.

PART SELECTION SUPPORT

Need Help Finding the Right Electrical, Specialty Fuses?

Send your target specifications, preferred brand, reference part number and quantity. Our team can help review matching options, stock availability and quotation details.

Egoo Store Egoo Store BOM BOM Cart My Inquiry Account My Account