Gas Discharge Tube Arresters (GDT)
Compare the current Gas Discharge Tube Arresters (GDT) Circuit Protection selection by manufacturer, stock status, datasheet and technical parameters. Use these details to narrow the list to parts that match your design, maintenance or purchasing requirements.
For a specific MPN, package, electrical rating or quantity requirement, send the details to EGOO. We can help confirm availability, quotation and alternative sourcing options.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SL1024A500RFGDT 500V 10KA 3 POLE TH |
3,274 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1024A | Tray | Obsolete | 500 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1024A600RFGDT 600V 10KA 3 POLE TH |
6,048 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1024A | Tray | Obsolete | 600 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A450RGGDT 450V 10KA 3 POLE TH |
2,415 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 450 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A420RGGDT 420V 10KA 3 POLE TH |
7,933 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 420 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A400RGGDT 400V 10KA 3 POLE TH |
6,422 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 400 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A260RGGDT 260V 10KA 3 POLE TH |
6,310 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 260 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A300RGGDT 300V 10KA 3 POLE TH |
2,286 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 300 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A600RGGDT 600V 10KA 3 POLE TH |
6,502 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 600 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A250RGGDT 250V 10KA 3 POLE TH |
7,649 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 250 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SL1021A230RGGDT 230V 10KA 3 POLE TH |
8,741 | - |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Obsolete | 230 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
Gas Discharge Tube Arresters (GDT) FAQ
How can I narrow the current Gas Discharge Tube Arresters (GDT) selection?
Use the available manufacturer and technical filters to compare matching parts by specifications, stock status, pricing and datasheet information.
Can EGOO help source hard-to-find or obsolete Gas Discharge Tube Arresters (GDT) parts?
Yes. Send the manufacturer part number and required quantity to our sourcing team for availability, lead-time and alternative sourcing support.
Can I request a quotation for a BOM or small-batch requirement?
Yes. EGOO supports BOM sourcing, prototype quantities and small-batch purchasing. Provide your part list and quantities for a quotation review.
What information should I provide when requesting a quote?
Please provide the target part number, manufacturer, quantity and any required date code, package or delivery requirements so our team can respond more accurately.