| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Q5-NO-100P-O-XSENSOR NITRIC OX -20-50DEGC OUT |
3,216 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Nitric Oxide (NO) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
Q5-SO2-6P-O-XSENSOR SULF DIOX -20-50DEGC OUT |
1,468 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Sulfur Dioxide (SO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-H2-1000P-O-XSENSOR HYDROGEN -20-50DEGC OUT |
4,693 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-NO-100P-O-XSENSOR NITRIC OX -20-50DEGC OUT |
2,061 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Nitric Oxide (NO) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
Q5-ETO-20P-O-XSENSOR ETO -20DEGC-50DEGC OUTPUT |
3,227 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Ethylene Oxide (ETO) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
QTS-61211X-E000000SENSOR HYDROGEN -20-50DEGC OUT |
4,952 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | ±2.5% | 4mA ~ 20mA | -20°C ~ 50°C | 12V ~ 36V | 25mA |
|
Q5-H2-2000P-O-XSENSOR HYDROGEN -20-50DEGC OUT |
2,078 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-H2-2000P-O-XSENSOR HYDROGEN -20-50DEGC OUT |
2,534 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-SO2-6P-O-XSENSOR SULF DIOX -20-50DEGC OUT |
1,439 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Sulfur Dioxide (SO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-ETO-20P-O-XSENSOR ETO -20DEGC-50DEGC OUTPUT |
2,594 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Ethylene Oxide (ETO) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
Q5-H2-1000P-O-XSENSOR HYDROGEN -20-50DEGC OUT |
3,651 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
85930-018-297SENSOR PHOSPHINE |
1,476 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Phosphine (PH3) | - | - | - | - | - | - |
|
85930-018-096SENSOR ARSINE |
3,428 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Arsine (AsH3) | - | - | - | - | - | - |
|
85930-018-097SENSOR PHOSPHINE |
3,710 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Phosphine (PH3) | - | - | - | - | - | - |
|
QTS-61211X-S00000SENSOR HYDROGEN -20-50DEGC OUT |
3,268 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen (H2) | - | ±2.5% | 4mA ~ 20mA | -20°C ~ 50°C | 12V ~ 36V | 25mA |
|
Q5-HCL-30P-O-XSENSOR SMART HYDROGEN CHLORIDE |
4,212 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Hydrogen Chloride (HCL) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
Q5-O3-1P-O-XSENSOR OZONE -20-50DEGC OUTPUT |
2,256 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Ozone (O3) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B5-O3-1P-O-XSENSOR OZONE -20-50DEGC OUTPUT |
1,644 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Ozone (O3) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
Q5-CLO2-2P-O-XSENSOR SMART CHLORINE DIOX |
4,452 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Chlorine Dioxide (CLO2) | - | - | 1V ~ 5V, 2V ~ 10V, 4mA ~ 20mA, RS485 | -20°C ~ 50°C | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
|
B8-C3H8-100L-O-XSENSOR PROPANE |
4,330 | - |
|
Datasheet | - | Tape & Box (TB) | Active | Propane (C3H8) | - | - | RS485 | - | 15VAC ~ 24VAC, 18VDC ~ 30VDC | 300mA |
Gas Sensors FAQ
What Gas Sensors components can I source from EGOO?
You can browse available Gas Sensors product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Gas Sensors parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.