REFINED COMPONENT RESULTS

Power Relays, Over 2 Amps

Compare the current Power Relays, Over 2 Amps Relays selection by manufacturer, stock status, datasheet and technical parameters. Use these details to narrow the list to parts that match your design, maintenance or purchasing requirements.

For a specific MPN, package, electrical rating or quantity requirement, send the details to EGOO. We can help confirm availability, quotation and alternative sourcing options.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Load - Max Switching Coil Current Coil Type Features Termination Style Seal Rating Coil Insulation Must Operate Voltage Must Release Voltage Operate Time Release Time Operating Temperature Contact Material Relay Type Grade Qualification
AZ7555-1A-24DKE American Zettler

AZ7555-1A-24DKE

RELAY GEN PURPOSE SPST 20A 24V

American Zettler

1,577 -
Datasheet AZ7555 Box Active Through Hole 24VDC SPST-NO (1 Form A) 20 A 277VAC, 30VDC - Max 5000VA, 480W 29.3 mA Non Latching - PC Pin Sealed - Fully - 16.8 VDC 2.4 VDC 15 ms 8 ms -40°C ~ 85°C Silver Tin Oxide (AgSnO) General Purpose - -
AZ770-1A-5DE American Zettler

AZ770-1A-5DE

RELAY GENERAL PURPOSE SPST 5A 5V

American Zettler

1,837 -
Datasheet AZ770 Box Active Through Hole 5VDC SPST-NO (1 Form A) 5 A 250VAC, 30VDC - Max - 90.9 mA Non Latching - PC Pin Sealed - Fully Class F 3.75 VDC 0.25 VDC 8 ms 4 ms -40°C ~ 85°C Silver Nickel (AgNi) General Purpose - -
AZ767-1A-9DE American Zettler

AZ767-1A-9DE

RELAY GENERAL PURPOSE SPST 3A 9V

American Zettler

3,455 -
Datasheet AZ767 Box Active Through Hole 9VDC SPST-NO (1 Form A) 3 A 380VAC, 150VDC - Max 750VA, 90W 50 mA Non Latching - PC Pin Sealed - Fully Class B 6.75 VDC 0.45 VDC 8 ms 5 ms -40°C ~ 90°C Silver Cadmium Oxide (AgCdO) General Purpose - -
AZ940-1AE-18DSE American Zettler

AZ940-1AE-18DSE

RELAY GEN PURPOSE SPST 10A 18V

American Zettler

2,763 -
Datasheet AZ940 Box Active Through Hole 18VDC SPST-NO (1 Form A) 10 A 400VAC, 150VDC - Max 2770VA, 150W 11.3 mA Non Latching - PC Pin Sealed - Fully Class B 13.5 VDC 0.9 VDC 8 ms 5 ms -40°C ~ 90°C Silver Tin Oxide (AgSnO) General Purpose - -
AZ940-1AB-18DSE American Zettler

AZ940-1AB-18DSE

RELAY GEN PURPOSE SPST 10A 18V

American Zettler

2,452 -
Datasheet AZ940 Box Active Through Hole 18VDC SPST-NO (1 Form A) 10 A 400VAC, 150VDC - Max 2770VA, 150W 11.3 mA Non Latching - PC Pin Sealed - Fully Class B 13.5 VDC 0.9 VDC 8 ms 5 ms -40°C ~ 90°C Silver Nickel (AgNi) General Purpose - -
AZ767-1A-12DE American Zettler

AZ767-1A-12DE

RELAY GEN PURPOSE SPST 3A 12V

American Zettler

2,970 -
Datasheet AZ767 Box Active Through Hole 12VDC SPST-NO (1 Form A) 3 A 380VAC, 150VDC - Max 750VA, 90W 37.5 mA Non Latching - PC Pin Sealed - Fully Class B 9 VDC 0.6 VDC 8 ms 5 ms -40°C ~ 90°C Silver Cadmium Oxide (AgCdO) General Purpose - -
AZ7555-1A-12DKE American Zettler

AZ7555-1A-12DKE

RELAY GEN PURPOSE SPST 20A 12V

American Zettler

2,497 -
Datasheet AZ7555 Box Active Through Hole 12VDC SPST-NO (1 Form A) 20 A 277VAC, 30VDC - Max 5000VA, 480W 60 mA Non Latching - PC Pin Sealed - Fully - 8.4 VDC 1.2 VDC 15 ms 8 ms -40°C ~ 85°C Silver Tin Oxide (AgSnO) General Purpose - -
AZ7705T-1A-12DEF American Zettler

AZ7705T-1A-12DEF

RELAY GEN PURPOSE SPST 10A 12V

American Zettler

2,572 -
Datasheet AZ7705 Box Active Through Hole 12VDC SPST-NO (1 Form A) 10 A 277VAC, 30VDC - Max 1250VA, 150W 37.5 mA Non Latching - PC Pin Sealed - Fully Class F 8.4 VDC 1.2 VDC 15 ms 4 ms -30°C ~ 85°C Silver Alloy, Cadmium Free General Purpose - -
AZ940-1AB-12DSE American Zettler

AZ940-1AB-12DSE

RELAY GEN PURPOSE SPST 10A 12V

American Zettler

1,145 -
Datasheet AZ940 Box Active Through Hole 12VDC SPST-NO (1 Form A) 10 A 400VAC, 150VDC - Max 2770VA, 150W 16.7 mA Non Latching - PC Pin Sealed - Fully Class B 9 VDC 0.6 VDC 8 ms 5 ms -40°C ~ 90°C Silver Nickel (AgNi) General Purpose - -
AZ940-1AB-5DSE American Zettler

AZ940-1AB-5DSE

RELAY GEN PURPOSE SPST 10A 5V

American Zettler

3,611 -
Datasheet AZ940 Box Active Through Hole 5VDC SPST-NO (1 Form A) 10 A 400VAC, 150VDC - Max 2770VA, 150W 40 mA Non Latching - PC Pin Sealed - Fully Class B 3.8 VDC 0.25 VDC 8 ms 5 ms -40°C ~ 90°C Silver Nickel (AgNi) General Purpose - -
Total 3030 Record«Prev1... 6566676869707172...303Next»

Power Relays, Over 2 Amps FAQ

How can I narrow the current Power Relays, Over 2 Amps selection?

Use the available manufacturer and technical filters to compare matching parts by specifications, stock status, pricing and datasheet information.

Can EGOO help source hard-to-find or obsolete Power Relays, Over 2 Amps parts?

Yes. Send the manufacturer part number and required quantity to our sourcing team for availability, lead-time and alternative sourcing support.

Can I request a quotation for a BOM or small-batch requirement?

Yes. EGOO supports BOM sourcing, prototype quantities and small-batch purchasing. Provide your part list and quantities for a quotation review.

What information should I provide when requesting a quote?

Please provide the target part number, manufacturer, quantity and any required date code, package or delivery requirements so our team can respond more accurately.

PART SELECTION SUPPORT

Need Help Finding the Right Power Relays, Over 2 Amps?

Send your target specifications, preferred brand, reference part number and quantity. Our team can help review matching options, stock availability and quotation details.

Egoo Store Egoo Store BOM BOM Cart My Inquiry Account My Account