Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Load - Max Switching Coil Current Coil Type Features Termination Style Seal Rating Coil Insulation Must Operate Voltage Must Release Voltage Operate Time Release Time Operating Temperature Contact Material Relay Type Grade Qualification
2961529 Phoenix Contact

2961529

RELAY GEN PURPOSE SPDT 16A 230V

Phoenix Contact

3,945 -
Datasheet REL-MR Bulk Active Through Hole 230VAC SPDT (1 Form C) 16 A 250VAC, 250VDC - Max - 3 mA Non Latching - PC Pin - - - - 12 ms 9 ms -40°C ~ 85°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
2961422 Phoenix Contact

2961422

RELAY GEN PURPOSE SPDT 16A 230V

Phoenix Contact

4,665 -
Datasheet REL-MR Tube Active Through Hole 230VAC SPDT (1 Form C) 16 A 250VAC, 250VDC - Max - 2.5 mA Non Latching - PC Pin - - - - 12 ms 9 ms -40°C ~ 85°C Silver Nickel (AgNi) General Purpose - -
2903304 Phoenix Contact

2903304

RELAY GEN PURPOSE 4PDT 5A 230V

Phoenix Contact

3,308 -
Datasheet RIF Bulk Active DIN Rail 230VAC 4PDT (4 Form C) 5 A 250VAC, 250VDC - Max - 6.5 mA Non Latching Lighted Indicator, Socket Included, Varistor Spring Terminal - - - - 15 ms 20 ms -40°C ~ 50°C Silver Nickel (AgNi) General Purpose - -
2903709 Phoenix Contact

2903709

RELAY GEN PURPOSE 3PST 16A 230V

Phoenix Contact

4,745 -
Datasheet REL-PR3 - Active Socketable 230VAC 3PST-NO (3 Form A) 16 A 440VAC, 250VDC - Max 7040VA, 4000W 12 mA Non Latching - Plug In - - - - 25 ms 20 ms -40°C ~ 55°C Silver Nickel (AgNi) General Purpose - -
2961370 Phoenix Contact

2961370

RELAY GEN PURPOSE SPDT 6A 4.5V

Phoenix Contact

3,884 -
Datasheet REL-MR Bulk Active Through Hole 4.5VDC SPDT (1 Form C) 6 A 250VAC - Max 1500VA 38 mA Non Latching - PC Pin - - - - 5 ms 2.5 ms -40°C ~ 85°C Silver Tin Oxide (AgSnO), Gold (Au) General Purpose - -
1078686 Phoenix Contact

1078686

RELAY GEN PURPOSE SPST 6A 24V

Phoenix Contact

4,933 -
Datasheet RIF Box Active DIN Rail 24VDC SPST-NO (1 Form A) 6 A 250VAC, 250VDC - Max - 18 mA Non Latching Diode, Lighted Indicator, Socket Included Spring Terminal - - - - 8 ms 10 ms -40°C ~ 70°C Silver Tin Oxide (AgSnO) General Purpose - -
2910110 Phoenix Contact

2910110

RELAY GEN PURPOSE SPDT 6A 230V

Phoenix Contact

1,135 -
Datasheet - Box Active DIN Rail 230VAC/DC SPDT (1 Form C) 6 A 250VAC, 250VDC - Max - 10 mA Non Latching Lighted Indicator, Socket Included Spring Terminal - - - - 7 ms 20 ms -40°C ~ 55°C Silver Tin Oxide (AgSnO) General Purpose - -
2966223 Phoenix Contact

2966223

RELAY GEN PURPOSE SPST 6A 24V

Phoenix Contact

4,847 -
Datasheet PLC-RSC Bulk Active DIN Rail 24VDC SPST-NO (1 Form A) 6 A 250VAC, 250VDC - Max - 9 mA Non Latching Lighted Indicator, Socket Included Screw Terminal - - - - 5 ms 8 ms -25°C ~ 60°C Silver Tin Oxide (AgSnO) General Purpose - -
2900301 Phoenix Contact

2900301

RELAY GEN PURPOSE SPDT 6A 48V

Phoenix Contact

4,562 -
Datasheet PLC-RPT Bulk Active DIN Rail 48VDC SPDT (1 Form C) 6 A 250VAC, 250VDC - Max - 9.2 mA Non Latching Lighted Indicator, Socket Included Spring Terminal - - - - 5 ms 8 ms -40°C ~ 60°C Silver Tin Oxide (AgSnO) General Purpose - -
2909532 Phoenix Contact

2909532

RELAY GEN PURPOSE SPDT 10A 24V

Phoenix Contact

2,967 -
Datasheet PLC-RPT Bulk Active DIN Rail 24VDC SPDT (1 Form C) 10 A 250VAC, 250VDC - Max - 18 mA Non Latching Lighted Indicator, Socket Included Spring Terminal - - - - 8 ms 10 ms -40°C ~ 60°C Silver Nickel (AgNi) General Purpose - -
Total 739 Record«Prev1... 910111213141516...74Next»

Power Relays, Over 2 Amps FAQ

How can I narrow the current Power Relays, Over 2 Amps selection?

Use the available manufacturer and technical filters to compare matching parts by specifications, stock status, pricing and datasheet information.

Can EGOO help source hard-to-find or obsolete Power Relays, Over 2 Amps parts?

Yes. Send the manufacturer part number and required quantity to our sourcing team for availability, lead-time and alternative sourcing support.

Can I request a quotation for a BOM or small-batch requirement?

Yes. EGOO supports BOM sourcing, prototype quantities and small-batch purchasing. Provide your part list and quantities for a quotation review.

What information should I provide when requesting a quote?

Please provide the target part number, manufacturer, quantity and any required date code, package or delivery requirements so our team can respond more accurately.

PART SELECTION SUPPORT

Need Help Finding the Right Power Relays, Over 2 Amps?

Send your target specifications, preferred brand, reference part number and quantity. Our team can help review matching options, stock availability and quotation details.

Egoo Store Egoo Store BOM BOM Cart My Inquiry Account My Account