Power Relays, Over 2 Amps
Compare the current Power Relays, Over 2 Amps Relays selection by manufacturer, stock status, datasheet and technical parameters. Use these details to narrow the list to parts that match your design, maintenance or purchasing requirements.
For a specific MPN, package, electrical rating or quantity requirement, send the details to EGOO. We can help confirm availability, quotation and alternative sourcing options.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Load - Max Switching | Coil Current | Coil Type | Features | Termination Style | Seal Rating | Coil Insulation | Must Operate Voltage | Must Release Voltage | Operate Time | Release Time | Operating Temperature | Contact Material | Relay Type | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
J1524CT110VACDTRELAY GEN PURPOSE 4PDT 10A 110V |
162 | - |
|
Datasheet | J152 | Tray | Active | Socketable | 110VAC | 4PDT (4 Form C) | 10 A | 300VAC - Max | 3000VA | 29.3 mA | Non Latching | Lighted Indicator, Test Button | Plug In | - | - | 88 VAC | 33 VAC | 25 ms | 25 ms | -40°C ~ 85°C | Silver Cadmium Oxide (AgCdO) | General Purpose | - | - |
|
J1071AS9VDC.36RELAY GEN PURPOSE SPST N.O. 15A |
1,821 | - |
|
Datasheet | J107 | Box | Active | Through Hole | 9VDC | SPST-NO (1 Form A) | 15 A | 125VAC, 30VDC - Max | 1875VA, 450W | 40 mA | Non Latching | - | PC Pin | Sealed - Fully | Class F | 6.75 VDC | 0.9 VDC | 10 ms | 10 ms | -40°C ~ 125°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1071AS18VDC.36RELAY GEN PURPOSE SPST N.O. 15A |
1,971 | - |
|
Datasheet | J107 | Box | Active | Through Hole | 18VDC | SPST-NO (1 Form A) | 15 A | 125VAC, 30VDC - Max | 1875VA, 450W | 20 mA | Non Latching | - | PC Pin | Sealed - Fully | Class F | 13.5 VDC | 1.8 VDC | 10 ms | 10 ms | -40°C ~ 125°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1071AS6VDC.36RELAY GEN PURPOSE SPST N.O. 15A |
1,953 | - |
|
Datasheet | J107 | Box | Active | Through Hole | 6VDC | SPST-NO (1 Form A) | 15 A | 125VAC, 30VDC - Max | 1875VA, 450W | 60 mA | Non Latching | - | PC Pin | Sealed - Fully | Class F | 4.5 VDC | 0.6 VDC | 10 ms | 10 ms | -40°C ~ 125°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1071AS48VDC.36RELAY GEN PURPOSE SPST N.O. 15A |
1,709 | - |
|
Datasheet | J107 | Box | Active | Through Hole | 48VDC | SPST-NO (1 Form A) | 15 A | 125VAC, 30VDC - Max | 1875VA, 450W | 7.5 mA | Non Latching | - | PC Pin | Sealed - Fully | Class F | 36 VDC | 4.8 VDC | 10 ms | 10 ms | -40°C ~ 125°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1071CS48VDC.36RELAY GEN PURPOSE SPDT 15A 30VDC |
1,941 | - |
|
Datasheet | J107 | Box | Active | Through Hole | 48VDC | SPDT (1 Form C) | 15 A | 125VAC, 30VDC - Max | 1875VA, 450W | 7.5 mA | Non Latching | - | PC Pin | Sealed - Fully | Class F | 36 VDC | 4.8 VDC | 10 ms | 10 ms | -40°C ~ 125°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1181CS24VDC.60RELAY GEN PURPOSE SPDT 10A 24VDC |
790 | - |
|
Datasheet | J118 | Tube | Active | Through Hole | 24VDC | SPDT (1 Form C) | 10 A | 380VAC, 110VDC - Max | 3800VA, 1100W | 25 mA | Non Latching | - | PC Pin | - | - | 18 VDC | 2.4 VDC | 10 ms | 5 ms | -40°C ~ 85°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1181CS9VDC.60RELAY GEN PURPOSE SPDT 10A 9VDC |
980 | - |
|
Datasheet | J118 | Tube | Active | Through Hole | 9VDC | SPDT (1 Form C) | 10 A | 380VAC, 110VDC - Max | 3800VA, 1100W | 66.7 mA | Non Latching | - | PC Pin | - | - | 6.75 VDC | 0.9 VDC | 10 ms | 5 ms | -40°C ~ 85°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1181AS12VDC.60RELAY GEN PURPOSE SPST N.O. 20A |
371 | - |
|
Datasheet | J118 | Tube | Active | Through Hole | 12VDC | SPST-NO (1 Form A) | 20 A | 380VAC, 110VDC - Max | 7600VA, 2200W | 50 mA | Non Latching | - | PC Pin | - | - | 9 VDC | 1.2 VDC | 10 ms | 5 ms | -40°C ~ 85°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
|
J1181AS24VDC.60RELAY GEN PURPOSE SPST N.O. 20A |
750 | - |
|
Datasheet | J118 | Tube | Active | Through Hole | 24VDC | SPST-NO (1 Form A) | 20 A | 380VAC, 110VDC - Max | 7600VA, 2200W | 25 mA | Non Latching | - | PC Pin | - | - | 18 VDC | 2.4 VDC | 10 ms | 5 ms | -40°C ~ 85°C | Silver Tin Oxide (AgSnO) | General Purpose | - | - |
Power Relays, Over 2 Amps FAQ
How can I narrow the current Power Relays, Over 2 Amps selection?
Use the available manufacturer and technical filters to compare matching parts by specifications, stock status, pricing and datasheet information.
Can EGOO help source hard-to-find or obsolete Power Relays, Over 2 Amps parts?
Yes. Send the manufacturer part number and required quantity to our sourcing team for availability, lead-time and alternative sourcing support.
Can I request a quotation for a BOM or small-batch requirement?
Yes. EGOO supports BOM sourcing, prototype quantities and small-batch purchasing. Provide your part list and quantities for a quotation review.
What information should I provide when requesting a quote?
Please provide the target part number, manufacturer, quantity and any required date code, package or delivery requirements so our team can respond more accurately.