PRODUCT DIRECTORY

Power Relays, Over 2 Amps

Browse available Power Relays, Over 2 Amps components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.

If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Load - Max Switching Coil Current Coil Type Features Termination Style Seal Rating Coil Insulation Must Operate Voltage Must Release Voltage Operate Time Release Time Operating Temperature Contact Material Relay Type Grade Qualification
RV2H-1HG1-D12 IDEC

RV2H-1HG1-D12

LOW PROFILE 14MM 1C RELAY 12V

IDEC

1,410 -
Datasheet RV2 Bulk Active Through Hole 12VDC DPDT (2 Form C) 8 A 250VAC - Nom - 31.7 mA Non Latching - PC Pin - - 9.6 VDC 0.84 VDC 15 ms 15 ms -40°C ~ 55°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
RV2H-1HG1-D5 IDEC

RV2H-1HG1-D5

LOW PROFILE 14MM 1C RELAY 5V

IDEC

1,213 -
Datasheet RV2 Bulk Active Through Hole 5VDC DPDT (2 Form C) 8 A 250VAC - Nom - - Non Latching - PC Pin - - 4 VDC 0.35 VDC 15 ms 15 ms -40°C ~ 55°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
RV2H-1HG1-D9 IDEC

RV2H-1HG1-D9

LOW PROFILE 14MM 1C RELAY 9V

IDEC

4,834 -
Datasheet RV2 Bulk Active Through Hole 9VDC DPDT (2 Form C) 8 A 250VAC - Nom - 44.4 mA Non Latching - PC Pin - - 7.2 VDC 0.63 VDC 15 ms 15 ms -40°C ~ 55°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
PCLH-203A1S,000 TE Connectivity Potter & Brumfield Relays

PCLH-203A1S,000

RELAY GEN PURPOSE DPDT 15A 24V

TE Connectivity Potter & Brumfield Relays

3,533 -
Datasheet PCLH, OEG Tray Obsolete Socketable 24VAC DPDT (2 Form C) 15 A 120VAC - Max 1800VA 150 mA Non Latching - Plug In, Quick Connect - 0.187" (4.7mm) - Class F 19.2 VAC 7.2 VAC 20 ms 20 ms -40°C ~ 55°C Silver Cadmium Oxide (AgCdO) General Purpose - -
PCLH-205D1S,000 TE Connectivity Potter & Brumfield Relays

PCLH-205D1S,000

RELAY GEN PURPOSE DPDT 15A 110V

TE Connectivity Potter & Brumfield Relays

2,162 -
Datasheet PCLH, OEG Tray Obsolete Socketable 110VDC DPDT (2 Form C) 15 A 120VAC - Max 1800VA 10 mA Non Latching - Plug In, Quick Connect - 0.187" (4.7mm) - Class F 88 VDC 11 VDC 15 ms 8 ms -40°C ~ 55°C Silver Cadmium Oxide (AgCdO) General Purpose - -
PT52A512B TE Connectivity Potter & Brumfield Relays

PT52A512B

RELAY GEN PURPOSE 4PDT 6A 12V

TE Connectivity Potter & Brumfield Relays

3,211 -
Datasheet PTH, SCHRACK Bulk Obsolete Socketable 12VAC 4PDT (4 Form C) 6 A 250VAC - Max 1500VA 83.3 mA Non Latching - Plug In - - 9.6 VAC 3.6 VAC 20 ms 20 ms -45°C ~ 70°C Silver Nickel (AgNi) General Purpose - -
AZ2704-1A-3DW American Zettler

AZ2704-1A-3DW

RELAY GEN PURPOSE SPST 30A 3V

American Zettler

4,571 -
Datasheet AZ2704 Box Active Through Hole 3VDC SPST-NO (1 Form A) 30 A 400VAC, 150VDC - Max 8310VA, 840W 600 mA Non Latching - PC Pin - Class B 2.25 VDC 0.15 VDC 30 ms 30 ms -40°C ~ 85°C Silver Cadmium Oxide (AgCdO) General Purpose - -
40.61.9.024.0001 Finder Relays, Inc.

40.61.9.024.0001

RELAY GEN PURPOSE SPDT 16A 24V

Finder Relays, Inc.

4,223 -
Datasheet 40 Bulk Obsolete Socketable 24VDC SPDT (1 Form C) 16 A 400VAC - Max 6400VA 27 mA Non Latching - Plug In - - 17.5 VDC 4.8 VDC 7 ms 3 ms -40°C ~ 85°C Silver Cadmium Oxide (AgCdO) General Purpose - -
40.61.7.024.0001 Finder Relays, Inc.

40.61.7.024.0001

RELAY GEN PURPOSE SPDT 16A 24V

Finder Relays, Inc.

2,402 -
Datasheet 40 Bulk Obsolete Socketable 24VDC SPDT (1 Form C) 16 A 400VAC - Max 6400VA 21 mA Non Latching - Plug In - - 17.5 VDC 4.8 VDC 7 ms 3 ms -40°C ~ 85°C Silver Cadmium Oxide (AgCdO) General Purpose - -
T9AS5D22-22 TE Connectivity Potter & Brumfield Relays

T9AS5D22-22

RELAY GEN PURPOSE SPDT 20A 22V

TE Connectivity Potter & Brumfield Relays

2,340 -
Datasheet T9A Bulk Active Through Hole 22VDC SPDT (1 Form C) 20 A 277VAC - Max 5540VA - Non Latching - PC Pin, Quick Connect - 0.250" (6.3mm) Sealed - Fully Class F 16.5 VDC 2.2 VDC 15 ms 15 ms -55°C ~ 85°C Silver Cadmium Oxide (AgCdO) General Purpose - -
ADW1224W Panasonic Electric Works

ADW1224W

RELAY GEN PURPOSE SPST 8A 24V

Panasonic Electric Works

3,496 -
Datasheet DW Tray Active Through Hole 24VDC SPST-NO (1 Form A) 8 A 250VAC - Max 2000VA 16.7 mA Latching, Dual Coil - PC Pin Sealed - Flux Protection Class F 19.2 VDC - 15 ms 15 ms -40°C ~ 85°C Silver Tin Oxide (AgSnO) General Purpose - -
G6B-1174P-US-P6B DC5 Omron Electronics Inc-EMC Div

G6B-1174P-US-P6B DC5

RELAY GEN PURPOSE SPST 8A 5V

Omron Electronics Inc-EMC Div

1,458 -
Datasheet G6B Bulk Active Socketable 5VDC SPST-NO (1 Form A) 8 A 380VAC, 125VDC - Max 3040VA, 1000W 40 mA Non Latching - Plug In Sealed - Fully - 3.5 VDC 0.5 VDC 10 ms 10 ms -25°C ~ 70°C Silver Alloy, Cadmium Free General Purpose - -
RV2H-1HG1-D24 IDEC

RV2H-1HG1-D24

LOW PROFILE 14MM 1C RELAY 24V

IDEC

3,804 -
Datasheet RV2 Bulk Active Through Hole 24VDC DPDT (2 Form C) 8 A 250VAC - Nom - 20 mA Non Latching - PC Pin - - 19.2 VDC 1.68 VDC 15 ms 15 ms -40°C ~ 55°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
RV2H-1HG1-D18 IDEC

RV2H-1HG1-D18

LOW PROFILE 14MM 1C RELAY 18V

IDEC

1,646 -
Datasheet RV2 Bulk Active Through Hole 18VDC DPDT (2 Form C) 8 A 250VAC - Nom - 23.9 mA Non Latching - PC Pin - - 14.4 VDC 1.26 VDC 15 ms 15 ms -40°C ~ 55°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
G2R-1A-E-ASI-DC12 Omron Electronics Inc-EMC Div

G2R-1A-E-ASI-DC12

RELAY GEN PURPOSE SPST 16A 12V

Omron Electronics Inc-EMC Div

3,820 -
Datasheet G2R Tray Obsolete Through Hole 12VDC SPST-NO (1 Form A) 16 A 380VAC, 125VDC - Max 6080VA, 2000W 43.6 mA Non Latching - PC Pin Sealed - Flux Protection - 8.4 VDC 1.8 VDC 15 ms 5 ms -40°C ~ 70°C Silver Alloy General Purpose - -
G2R-2A-ASI-DC12 Omron Electronics Inc-EMC Div

G2R-2A-ASI-DC12

RELAY GEN PURPOSE DPST 5A 12V

Omron Electronics Inc-EMC Div

1,163 -
Datasheet G2R Tray Obsolete Through Hole 12VDC DPST-NO (2 Form A) 5 A 380VAC, 125VDC - Max 1900VA, 625W 43.6 mA Non Latching - PC Pin Sealed - Flux Protection - 8.4 VDC 1.8 VDC 15 ms 5 ms -40°C ~ 70°C Silver Alloy General Purpose - -
AZ2700-1A-3D American Zettler

AZ2700-1A-3D

RELAY GEN PURPOSE SPST 30A 3V

American Zettler

1,356 -
Datasheet AZ2700 Box Active Chassis Mount 3VDC SPST-NO (1 Form A) 30 A 400VAC, 150VDC - Max 8310VA, 840W 600 mA Non Latching - Quick Connect - 0.250" (6.3mm) - Class B 2.25 VDC 0.15 VDC 30 ms 30 ms -40°C ~ 85°C Silver Cadmium Oxide (AgCdO) General Purpose - -
1393240-9 TE Connectivity Potter & Brumfield Relays

1393240-9

RELAY GEN PURPOSE SPDT 16A 5V

TE Connectivity Potter & Brumfield Relays

2,292 -
Datasheet RT1, SCHRACK Bulk Active Through Hole 5VDC SPDT (1 Form C) 16 A 400VAC - Max 6400VA 80.6 mA Non Latching - PC Pin Sealed - Flux Protection Class F 3.5 VDC 0.5 VDC 8 ms 6 ms -40°C ~ 85°C Silver Nickel (AgNi), Gold (Au) General Purpose - -
AZ2501P1-1C-6D American Zettler

AZ2501P1-1C-6D

RELAY GEN PURPOSE SPDT 50A 6V

American Zettler

2,390 -
Datasheet AZ2501 Box Active Through Hole 6VDC SPDT (1 Form C) 50 A 440VAC - Max 13850VA 250 mA Latching, Single Coil - PC Pin - - 4.8 VDC - 15 ms 15 ms -40°C ~ 70°C Silver Tin Oxide (AgSnO) General Purpose - -
PCLH-106A1S,000 TE Connectivity Potter & Brumfield Relays

PCLH-106A1S,000

RELAY GEN PURPOSE SPDT 15A 110V

TE Connectivity Potter & Brumfield Relays

4,075 -
Datasheet PCLH, OEG Bulk Obsolete Socketable 110VAC SPDT (1 Form C) 15 A 250VAC, 24VDC - Max 3750VA, 360W 32.4 mA Non Latching - Plug In, Quick Connect - 0.187" (4.7mm) - Class F 88 VAC 33 VAC 20 ms 20 ms -40°C ~ 55°C Silver Cadmium Oxide (AgCdO) General Purpose - -
Total 25983 Record«Prev1... 640641642643644645646647...1300Next»
COMPONENT SOURCING SUPPORT

Need Availability or Pricing for Power Relays, Over 2 Amps?

Share your target part numbers and quantities with our team for stock checks, lead-time information and quotation support. We can also assist with shortage, obsolete and alternative sourcing requirements.

Power Relays, Over 2 Amps FAQ

What Power Relays, Over 2 Amps components can I source from EGOO?

You can browse available Power Relays, Over 2 Amps product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.

Can EGOO help with hard-to-source or obsolete Power Relays, Over 2 Amps parts?

Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.

Does EGOO support BOM and small-batch sourcing?

Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.

How do I request pricing and availability?

Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.

Egoo Store Egoo Store BOM BOM Cart My Inquiry Account My Account