| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Type | Holding Temperature | Rated Functioning Temperature | Reset Temperature | Voltage Rating - AC | Voltage Rating - DC | Current Rating (Amps) | Approval Agency | Maximum Temperature Limit |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
USW-139TTHERMAL CUTOFF (THERMAL FUSE) 25 |
6,709 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 178°C (352°F) | 216°C (421°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-129TTHERMAL CUTOFF (THERMAL FUSE) 25 |
4,047 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 103°C (217°F) | 128°C (262°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-138TTHERMAL CUTOFF (THERMAL FUSE) 25 |
6,108 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 119°C (246°F) | 144°C (291°F) | - | 250.0 | - | 10 A | PSE | - |
|
USW-127TTHERMAL CUTOFF (THERMAL FUSE) 25 |
8,399 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 159°C (318°F) | 184°C (363°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-111TTHERMAL CUTOFF (THERMAL FUSE) 25 |
5,671 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 94°C (201°F) | 119°C (246°F) | - | 250.0 | - | 10 A | cUL, PSE, TUV, VDE, UL | - |
|
USW-109TTHERMAL CUTOFF (THERMAL FUSE) 25 |
9,160 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 57°C (135°F) | 84°C (183°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-104TTHERMAL CUTOFF (THERMAL FUSE) 25 |
2,787 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 73°C (163°F) | 98°C (208°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-110TTHERMAL CUTOFF (THERMAL FUSE) 25 |
8,455 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 84°C (183°F) | 109°C (228°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-102TTHERMAL CUTOFF (THERMAL FUSE) 25 |
7,913 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 47°C (117°F) | 72°C (162°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-108TTHERMAL CUTOFF (THERMAL FUSE) 25 |
4,200 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | 75°C (167°F) | 100°C (212°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
USW-152TTHERMAL CUTOFF (THERMAL FUSE) 25 |
3,264 | - |
|
Datasheet | Axial | SW-1 | Bag | Active | Fuse | - | - | - | 250.0 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
|
KG1ALLOY THERMAL CUTOFF |
9,719 | - |
|
Datasheet | Radial | KG | Bulk | Active | Fuse | 79°C (174°F) | 102°C (216°F) | - | 250.0 | 60.0 | 2 A | CCC, cUL, PSE, TUV, UL | 200°C (392°F) |
|
K7ALLOY THERMAL CUTOFF |
4,805 | - |
|
Datasheet | Radial | K | Bulk | Active | Fuse | 126°C (259°F) | 150°C (302°F) | - | 250.0 | - | 2 A | CCC, cUL, KC, PSE, UL, VDE | 200°C (392°F) |
|
Y4ALLOY THERMAL CUTOFF |
8,870 | - |
|
Datasheet | Radial | Y | Bulk | Active | Fuse | 103°C (217°F) | 130°C (266°F) | - | 300.0 | - | 5 A | cUL, TUV, UL | 200°C (392°F) |
|
S102ALLOY THERMAL CUTOFF |
3,933 | - |
|
Datasheet | Radial | S | Bulk | Active | Fuse | 72°C (162°F) | 102°C (216°F) | - | 250.0 | - | 5 A | CCC, cUL, PSE, UL, VDE | 200°C (392°F) |
|
X6ALLOY THERMAL CUTOFF |
7,056 | - |
|
Datasheet | Radial | X | Bulk | Active | Fuse | 121°C (250°F) | 145°C (293°F) | - | 250.0 | 60.0 | 4 A | CCC, cUL, KC, PSE, UL, VDE | 200°C (392°F) |
|
B2ALLOY THERMAL CUTOFF |
5,481 | - |
|
Datasheet | Axial | B | Bulk | Active | Fuse | 91°C (196°F) | 115°C (239°F) | - | 250.0 | 50.0 | 3 A | CCC, cUL, KTL, PSE, TUV, UL | 200°C (392°F) |
|
|
H2ALLOY THERMAL CUTOFF |
4,240 | - |
|
Datasheet | Axial | H | Bulk | Active | Fuse | 91°C (196°F) | 115°C (239°F) | - | 250.0 | 50.0 | 2 A | CCC, cUL, KTL, PSE, TUV | 200°C (392°F) |
|
KM7ALLOY THERMAL CUTOFF |
2,754 | - |
|
Datasheet | Radial | KM | Bulk | Active | Fuse | 126°C (259°F) | 150°C (302°F) | - | 300.0 | - | 2 A | cUL, TUL, UL | 200°C (392°F) |
|
X7ALLOY THERMAL CUTOFF |
7,053 | - |
|
Datasheet | Radial | X | Bulk | Active | Fuse | 126°C (259°F) | 150°C (302°F) | - | 250.0 | - | 3 A | CCC, cUL, KC, PSE, UL, VDE | 200°C (392°F) |
Thermal Cutoffs (Thermal Fuses) FAQ
What Thermal Cutoffs (Thermal Fuses) components can I source from EGOO?
You can browse available Thermal Cutoffs (Thermal Fuses) product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Thermal Cutoffs (Thermal Fuses) parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.