Single IGBTs
Browse available Single IGBTs components by manufacturer and part number. Review stock status, datasheets and key technical parameters to compare suitable options for design, maintenance, replacement or purchasing.
If you already have a target MPN or BOM, send it to EGOO with the required quantity. Our sourcing team can check availability, lead time and quotation options, including hard-to-find and obsolete parts.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | IGBT Type | Voltage - Collector Emitter Breakdown (Max) | Current - Collector (Ic) (Max) | Current - Collector Pulsed (Icm) | Vce(on) (Max) @ Vge, Ic | Power - Max | Switching Energy | Input Type | Gate Charge | Td (on/off) @ 25°C | Test Condition | Reverse Recovery Time (trr) | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AFGHL40T65SPDIGBT TRENCH FS 650V 80A TO247-3 |
855 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 120 A | 2.4V @ 15V, 40A | 267 W | 1.16mJ (on), 270µJ (off) | Standard | 36 nC | 18ns/35ns | 400V, 40A, 6Ohm, 15V | 35 ns | -55°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | TO-247-3 |
|
RGS30TSX2GC11IGBT TRENCH FLD 1200V 30A TO247N |
440 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 30 A | 45 A | 2.1V @ 15V, 15A | 267 W | 740µJ (on), 600µJ (off) | Standard | 41 nC | 30ns/70ns | 600V, 15A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGW00TS65CHRC11IGBT 650V 96A TO247N |
414 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | - | 650 V | 96 A | 200 A | 1.9V @ 15V, 50A | 254 W | 180µJ (on), 420µJ (off) | Standard | 141 nC | 49ns/180ns | 400V, 25A, 10Ohm, 15V | 33 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGSX5TS65EGC11IGBT TRENCH FLD 650V 114A TO247N |
424 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 114 A | 225 A | 2.15V @ 15V, 75A | 404 W | 3.44mJ (on), 1.9mJ (off) | Standard | 79 nC | 43ns/113ns | 400V, 75A, 10Ohm, 15V | 116 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
AFGHL50T65SQAEC 101 QUALIFIED, 650V, 50A FIE |
429 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 200 A | 2.1V @ 15V, 50A | 268 W | 950µJ (on), 460µJ (off) | Standard | 99 nC | 20ns/81ns | 400V, 50A, 4.7Ohm, 15V | - | -55°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | TO-247-3 |
|
RJH65T46DPQ-A0#T0IGBT TRENCH 650V 80A TO247A |
385 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench | 650 V | 80 A | - | 2.4V @ 15V, 40A | 340.9 W | 450µJ (on), 550µJ (off) | Standard | 138 nC | 45ns/170ns | 400V, 40A, 10Ohm, 15V | 100 ns | 175°C (TJ) | - | - | Through Hole | TO-247A |
|
RGTH40TS65GC13IGBT TRENCH FS 650V 40A TO247G |
600 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 40 A | 80 A | 2.1V @ 15V, 20A | 144 W | - | Standard | 40 nC | 22ns/73ns | 400V, 20A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247G |
|
RGW50TS65GC11IGBT TRNCH FIELD 650V 50A TO247N |
450 | - |
|
Datasheet | - | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 50 A | 100 A | 1.9V @ 15V, 25A | 156 W | 390µJ (on), 430µJ (off) | Standard | 73 nC | 35ns/102ns | 400V, 25A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
AFGB30T65SQDN650V/30A FS4 IGBT TO263 A |
780 | - |
|
Datasheet | EcoSPARK® | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | - | 650 V | 60 A | 120 A | 2.1V @ 15V, 30A | 220 W | - | Standard | 56 nC | 14.5ns/63.2ns | 400V, 30A, 6Ohm, 15V | 245 ns | -55°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Surface Mount | TO-263 (D2PAK) |
|
RGS30TSX2HRC11IGBT TRENCH FLD 1200V 30A TO247N |
492 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 30 A | 45 A | 2.1V @ 15V, 15A | 267 W | 740µJ (on), 600µJ (off) | Standard | 41 nC | 30ns/70ns | 600V, 15A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGCL60TS60DGC11IGBT TRNCH FIELD 600V 48A TO247N |
169 | - |
|
Datasheet | - | TO-247-3 | Bulk | Not For New Designs | Trench Field Stop | 600 V | 48 A | 120 A | 1.8V @ 15V, 30A | 111 W | 770µJ (on), 1.11mJ (off) | Standard | 68 nC | 44ns/186ns | 400V, 30A, 10Ohm, 15V | 58 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGW60TS65DGC11IGBT TRNCH FIELD 650V 60A TO247N |
450 | - |
|
Datasheet | - | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 60 A | 120 A | 1.9V @ 15V, 30A | 178 W | 480µJ (on), 490µJ (off) | Standard | 84 nC | 37ns/114ns | 400V, 30A, 10Ohm, 15V | 92 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGTH50TS65GC13IGBT TRNCH FIELD 650V 50A TO247G |
580 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 50 A | 100 A | 2.1V @ 15V, 25A | 174 W | - | Standard | 49 nC | 27ns/94ns | 400V, 25A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247G |
|
RGS60TS65DHRC11IGBT TRNCH FIELD 650V 56A TO247N |
450 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 56 A | 90 A | 2.1V @ 15V, 30A | 223 W | 660µJ (on), 810µJ (off) | Standard | 36 nC | 28ns/104ns | 400V, 30A, 10Ohm, 15V | 103 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
RGW00TK65DGVC11IGBT TRNCH FIELD 650V 45A TO3PFM |
425 | - |
|
Datasheet | - | TO-3PFM, SC-93-3 | Tube | Active | Trench Field Stop | 650 V | 45 A | 200 A | 1.9V @ 15V, 50A | 89 W | 1.18mJ (on), 960µJ (off) | Standard | 141 nC | 52ns/180ns | 400V, 50A, 10Ohm, 15V | 95 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-3PFM |
|
STGWA50M65DF2TRENCH GATE FIELD-STOP IGBT M SE |
280 | - |
|
Datasheet | M | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 150 A | 2.1V @ 15V, 50A | 375 W | 880µJ (on), 1.57mJ (off) | Standard | 150 nC | 42ns/130ns | 400V, 50A, 6.8Ohm, 15V | 162 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 Long Leads |
|
RGW60TS65GC11IGBT TRNCH FIELD 650V 60A TO247N |
420 | - |
|
Datasheet | - | TO-247-3 | Tube | Not For New Designs | Trench Field Stop | 650 V | 60 A | 120 A | 1.9V @ 15V, 30A | 178 W | 480µJ (on), 490µJ (off) | Standard | 84 nC | 37ns/114ns | 400V, 30A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | TO-247N |
|
AIKW30N60CTXKSA1IGBT TRENCH FS 600V 60A TO247-3 |
254 | - |
|
Datasheet | TrenchStop™ | TO-247-3 | Tube | Active | Trench Field Stop | 600 V | 60 A | 90 A | 2.05V @ 15V, 30A | 187 W | 690µJ (on), 770µJ (off) | Standard | 167 nC | 23ns/254ns | 400V, 30A, 10.6Ohm, 15V | - | -40°C ~ 175°C (TJ) | Automotive | AEC-Q101 | Through Hole | PG-TO247-3-41 |
|
FGHL50T65MQDTFS4 MID SPEED IGBT 650V 50A TO24 |
725 | - |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 200 A | 1.8V @ 15V, 40A | 268 W | 1.19mJ (on), 630µJ (off) | Standard | 99 nC | 21ns/90ns | 400V, 50A, 6Ohm, 15V | 79 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247-3 |
|
AOK50B65M2IGBT 650V 50A TO247 |
199 | - |
|
Datasheet | Alpha IGBT™ | TO-247-3 | Tube | Active | - | 650 V | 100 A | 150 A | 2.2V @ 15V, 50A | 500 W | 2.09mJ (on), 1.03mJ (off) | Standard | 102 nC | 46ns/182ns | 400V, 50A, 6Ohm, 15V | 327 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
Single IGBTs FAQ
What Single IGBTs components can I source from EGOO?
You can browse available Single IGBTs product families, manufacturers and part numbers on this page, then review stock, datasheets and technical information for suitable options.
Can EGOO help with hard-to-source or obsolete Single IGBTs parts?
Yes. EGOO provides sourcing support for shortage, obsolete and hard-to-find electronic components. Send us the target manufacturer part number and quantity for checking.
Does EGOO support BOM and small-batch sourcing?
Yes. We support BOM sourcing, prototype requirements and small-batch supply, together with stock, lead-time and quotation assistance.
How do I request pricing and availability?
Submit the manufacturer part number, required quantity and any package, date-code or delivery requirements through the RFQ form, and our team will review available sourcing options.